GoodWe DT/SDT/MS/XS/DNS string inverters
Inverter·5 integration routes·103 models on grid lists
Local control with Home Assistant and evcc
checked 2026-10-31
- Home Assistant
- localcontrol3 integrations
- evcc
- localread only
- Connection
- Modbus TCP, Modbus RTU (RS485), UDP (vendor protocol), Cloud API, LAN (vendor protocol)
Does GoodWe DT/SDT/MS/XS/DNS string inverters work locally with Home Assistant?
Yes, according to the public sources: the HA core integration “GoodWe Inverter” and the HACS integration “GoodWe Inverter” talks to it over the local network and exposes settable entities, not only sensors; evcc supports it locally for metering.
Firmware updates can open or close local access — check the integration's own page before you buy, and your installer before software changes export limits or charges a battery from the grid.
Evidence: integrations and templates
| Integration | Source | Link | Read or control | Connection | Repo | Seen |
|---|---|---|---|---|---|---|
| GoodWe Inverter | Home Assistant core | local | control settable entities: number, select, button | UDP (vendor protocol), Modbus TCP (local_polling) | – | 2026-10-31 |
| GoodWe Inverter mletenay/home-assistant-goodwe-inverter | HACS custom integration | local | control settable entities: number, select, switch, button | UDP (vendor protocol), Modbus TCP (local_polling) | ★ 240 · 2026-07-01 | 2026-10-31 |
| GoodWe SEMS API TimSoethout/goodwe-sems-home-assistant | HACS custom integration | cloud | control settable entities: number, select, switch | Cloud API (cloud_polling) | ★ 147 · 2026-10-23 | 2026-10-31 |
| goodwe-dt (SDT/DT Inverter) | evcc template | local | read only metering only | Modbus TCP, Modbus RTU (RS485) | – | 2026-10-31 |
| goodwe-wifi-dt (SDT/DT Inverter (WiFi)) | evcc template | local | read only metering only | LAN (vendor protocol) | – | 2026-10-31 |
Core integrations ship with Home Assistant. For the exact GoodWe models that Home Assistant users report, see theOpen Home Foundation Device Database (preview) — GridFit does not copy it.
Grid-connection lists
The list is the authority; this is a cross-reference.
Is the GoodWe DT/SDT/MS/XS/DNS string inverters on an EU grid-connection list?
Yes — models of this family are on the lists of AT, BE, CZ, EE, NL, PL, SE (lists dated up to 2026-10-30, read 2026-10-31); the other 0 of the 7 lists read have no matching model, which is not a “no”.
- ATAustria — listed with restrictions “Nein” · 37 rows · Austrian TOR Erzeuger Typ A list dated 2026-10-30, read 2026-10-31✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW100K-HT (+36 rows)open the list
- BEBelgium — listed · 76 rows · Belgian Synergrid C10/26 list dated 2026-10-30, read 2026-10-31✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW1000-XS (+75 rows)open the list
- CZCzechia — listed · approved firmware
V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319· 11 rows · Czech ČEZ Distribuce list dated 2026-08-21, read 2026-10-31✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319evidence: Protokol (EGD)as written: GoodWe · GW10K-SDT-20 (+10 rows)open the list - EEEstonia — listed · 59 rows · Estonian Elektrilevi inverter list, read 2026-10-31✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW1000-NS (+58 rows)open the list
- NLNetherlands — listed · 60 rows · Dutch Netbeheer Nederland type-A list dated 2026-10-30, read 2026-10-31✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW1000-XS (+59 rows)open the list
- PLPoland — listed · firmware
Główny SVN: 2011, podrzędny SVN: 2003· 13 rows · Polish PTPiREE WiPWC 1.3 list dated 2026-10-26, read 2026-10-31✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW10K-SDT-30 (+12 rows)open the list - SESweden — listed · firmware
V1.52· 58 rows · Swedish Rikta Rätt inverter list dated 2026-10-23, read 2026-10-31✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.52as written: GoodWe · GW1000-XS (+57 rows)open the list
36 more countries: what applies to a inverter there
No model rows for these countries — they publish no usable list, or GridFit has not parsed it yet. The state comes from the EU+ grid-connection table; each country page says more.
On a public list:GermanysDenmarkGreat BritainHungaryIrelandLatviaNorthern IrelandPortugalRomania
No list, a rule applies:AlbaniaBosnia and HerzegovinaSwitzerlandCyprusSpainFinlandFrancesGreecesCroatiasIcelandItalyLiechtensteinLithuaniaLuxembourgMoldovaMontenegroNorth MacedoniaMaltasNorwaySerbiaSloveniaSlovakiaTürkiyeUkrainesKosovo?
Not confirmed:Bulgaria?Georgias
s = from search results, ? = unverified; without a mark the page was opened.
Model codes on the lists
Matched to this family by model-code pattern (brand match alias / exact) — a pointer; confirm in the list. Hover a cell for the list's own words.
| Model, as the list writes it | AT | BE | CZ | EE | NL | PL | SE | MPPT | kW | Match |
|---|---|---|---|---|---|---|---|---|---|---|
| GW1000-NS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW1000-NSopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW1000-XS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW1000-XSopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW1000-XSopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW1000-XSopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.52as written: GoodWe · GW1000-XSopen the list | 1 | 1 | alias |
| GW1000-XS-11 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW1000-XS-11open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW1000-XS-11open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW1000-XS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW1000-XS-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW1000-XS-30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW100K-HT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW100K-HTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW100K-HTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW100K-HTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW100K-HTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.07.07as written: GoodWe · GW100K-HTopen the list | – | – | alias |
| GW10K-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW10K-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW10K-SDT-20 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW10K-SDT-20open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW10K-SDT-20open the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319evidence: Protokol (EGD)as written: GoodWe · GW10K-SDT-20open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW10K-SDT-20open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW10K-SDT-20open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.12.12.13as written: GoodWe · GW10K-SDT-20open the list | – | – | alias |
| GW10K-SDT-30 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: DSP FW:05.5008.05.5005; ARM FW:04.46; Communication Module F…as written: Goodwe · GW10K-SDT-30open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW10K-SDT-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW10K-SDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04as written: GoodWe · GW10K-SDT-30open the list | – | – | alias |
| GW10K-SDT-EU30 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: DSP FW:05.5008.05.5005; ARM FW:04.46; Communication Module F…as written: Goodwe · GW10K-SDT-EU30open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW10K-SDT-EU30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW10K-SDT-EU30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04as written: GoodWe · GW10K-SDT-EU30open the list | – | – | alias |
| GW10KN-DT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW10KN-DTopen the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW10KN-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW10KT-DT | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW10KT-DTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW10KT-DTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW10KT-DTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW10KT-DTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.10as written: GoodWe · GW10KT-DTopen the list | – | – | alias |
| GW110K-HT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW110K-HTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW110K-HTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW110K-HTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW110K-HTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.07.07as written: GoodWe · GW110K-HTopen the list | – | – | alias |
| GW120K-HT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW120K-HTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW120K-HTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW120K-HTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW120K-HTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.07.07as written: GoodWe · GW120K-HTopen the list | – | – | alias |
| GW12K-SDT-20 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW12K-SDT-20open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW12K-SDT-20open the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319evidence: Protokol (EGD)as written: GoodWe · GW12K-SDT-20open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW12K-SDT-20open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW12K-SDT-20open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.12.12.13as written: GoodWe · GW12K-SDT-20open the list | – | – | alias |
| GW12K-SDT-30 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: DSP FW:05.5008.05.5005; ARM FW:04.46; Communication Module F…as written: Goodwe · GW12K-SDT-30open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW12K-SDT-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW12K-SDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04as written: GoodWe · GW12K-SDT-30open the list | – | – | alias |
| GW12KN-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW12KN-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW12KT-DT | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW12KT-DTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW12KT-DTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW12KT-DTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW12KT-DTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.10as written: GoodWe · GW12KT-DTopen the list | – | – | alias |
| GW136K-HTH | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW136K-HTHopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW136K-HTHopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW136K-HTHopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW1500-NS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW1500-NSopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW1500-XS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW1500-XSopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW1500-XSopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW1500-XSopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.52as written: GoodWe · GW1500-XSopen the list | 1 | 1.5 | alias |
| GW1500-XS-11 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW1500-XS-11open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW1500-XS-11open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW1500-XS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW1500-XS-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW1500-XS-30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW15K-SDT-20 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW15K-SDT-20open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW15K-SDT-20open the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319evidence: Protokol (EGD)as written: GoodWe · GW15K-SDT-20open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW15K-SDT-20open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW15K-SDT-20open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.12.12.13as written: GoodWe · GW15K-SDT-20open the list | – | – | alias |
| GW15K-SDT-30 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: DSP FW:05.5008.05.5005; ARM FW:04.46; Communication Module F…as written: Goodwe · GW15K-SDT-30open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW15K-SDT-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW15KSDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04as written: GoodWe · GW15K-SDT-30open the list | – | – | alias |
| GW15KN-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW15KN-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW15KT-DT | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW15KT-DTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW15KT-DTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW15KT-DTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW15KT-DTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.10as written: GoodWe · GW15KT-DTopen the list | – | – | alias |
| GW17K-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW17K-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW17K-SDT-20 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW17K-SDT-20open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW17K-SDT-20open the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319evidence: Protokol (EGD)as written: GoodWe · GW17K-SDT-20open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW17K-SDT-20open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW17K-SDT-20open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.12.12.13as written: GoodWe · GW17K-SDT-20open the list | – | – | alias |
| GW17K-SDT-30 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: DSP FW:05.5008.05.5005; ARM FW:04.46; Communication Module F…as written: Goodwe · GW17K-SDT-30open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW17K-SDT-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW17K-SDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04as written: GoodWe · GW17K-SDT-30open the list | – | – | alias |
| GW17KN-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW17KN-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW17KT-DT | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW17KT-DTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW17KT-DTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW17KT-DTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW17KT-DTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.10as written: GoodWe · GW17KT-DTopen the list | – | – | alias |
| GW2000-NS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW2000-NSopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW2000-XS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW2000-XSopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW2000-XSopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW2000-XSopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.52as written: GoodWe · GW2000-XSopen the list | 1 | 2 | alias |
| GW2000-XS-11 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW2000-XS-11open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW2000-XS-11open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW2000-XS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW2000-XS-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW2000-XS-30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW20K-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW20K-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW20K-SDT-20 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW20K-SDT-20open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW20K-SDT-20open the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319evidence: Protokol (EGD)as written: GoodWe · GW20K-SDT-20open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW20K-SDT-20open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW20K-SDT-20open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.12.12.13as written: GoodWe · GW20K-SDT-20open the list | – | – | alias |
| GW20K-SDT-30 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: DSP FW:05.5008.05.5005; ARM FW:04.46; Communication Module F…as written: Goodwe · GW20K-SDT-30open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW20K-SDT-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW20K-SDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04as written: GoodWe · GW20K-SDT-30open the list | – | – | alias |
| GW20KT-DT | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW20KT-DTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW20KT-DTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW20KT-DTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW20KT-DTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.10as written: GoodWe · GW20KT-DTopen the list | – | – | alias |
| GW225K-HT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW225K-HTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW225K-HTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW225K-HTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW225KN-HT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW225KN-HTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW225KN-HTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW2500-NS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW2500-NSopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW2500-XS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW2500-XSopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW2500-XSopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW2500-XSopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.52as written: GoodWe · GW2500-XSopen the list | 1 | 2.5 | alias |
| GW2500-XS-11 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW2500-XS-11open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW2500-XS-11open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW2500-XS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW2500-XS-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW2500-XS-30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW250K-HT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW250K-HTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW250K-HTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW250K-HTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW250K-HTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW250KN-HT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW250KN-HTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW250KN-HTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW25K-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW25K-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW25K-MT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW25K-MTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW25K-MTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW25K-MTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.09.09.08as written: GoodWe · GW25K-MTopen the list | – | 25 | alias |
| GW25K-SDT-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: V1.00.00document: 6275790.01 COCas written: GoodWe (GuangDe) Power Supply Technology Co.,Ltd · GW25K-SDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.12.12.13as written: GoodWe · GW25K-SDT-30open the list | – | – | alias |
| GW25KT-DT | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW25KT-DTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW25KT-DTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW25KT-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.10as written: GoodWe · GW25KT-DTopen the list | – | – | alias |
| GW3000-DNS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW3000-DNS-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW3000-DNS-30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | 2 | 3 | exact |
| GW3000-NS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW3000-NSopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW3000-XS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW3000-XSopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW3000-XSopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW3000-XSopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.52as written: GoodWe · GW3000-XSopen the list | 1 | 3 | alias |
| GW3000-XS-11 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW3000-XS-11open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW3000-XS-11open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW3000-XS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW3000-XS-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW3000-XS-30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW3000D-NS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW3000D-NSopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW3000D-NSopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW3000D-NSopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.51as written: GoodWe · GW3000D-NSopen the list | 2 | 3 | alias |
| GW30K-MT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW30K-MTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW30K-MTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW30K-MTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW30K-MTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.09.09.08as written: GoodWe · GW30K-MTopen the list | – | 30 | alias |
| GW30K-SDT-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: V1.00.00document: 6275790.01 COCas written: GoodWe (GuangDe) Power Supply Technology Co.,Ltd · GW30K-SDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.12.12.13as written: GoodWe · GW30K-SDT-30open the list | – | – | alias |
| GW3300-XS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW3300-XS-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW3300-XS-30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | exact |
| GW3600-DNS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW3600-DNS-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW3600-DNS-30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | 2 | 3.6 | exact |
| GW3600D-NS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW3600D-NSopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW3600D-NSopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW3600D-NSopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.51as written: GoodWe · GW3600D-NSopen the list | 2 | 3.68 | alias |
| GW36K-MT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW36K-MTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW36K-MTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW36K-MTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW36K-MTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.09.09.08as written: GoodWe · GW36K-MTopen the list | – | 36 | alias |
| GW4000-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW4000-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW4000-SDT-20 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW4000-SDT-20open the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319evidence: Protokol (EGD)as written: GoodWe · GW4000-SDT-20open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW4000-SDT-20open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.14.14.15as written: GoodWe · GW4000-SDT-20open the list | – | – | exact |
| GW4000-SDT-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW4000-SDT-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW4000-SDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04as written: GoodWe · GW4000-SDT-30open the list | – | – | alias |
| GW40K-SDT-P30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: V1.00.00document: 6275790.01 COCas written: GoodWe (GuangDe) Power Supply Technology Co.,Ltd · GW40K-SDT-P30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.12.12.13as written: GoodWe · GW40K-SDT-P30open the list | – | – | alias |
| GW4200-DNS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW4200-DNS-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW4200-DNS-30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | 2 | 4.2 | exact |
| GW4200D-NS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW4200D-NSopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW4200D-NSopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW4200D-NSopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.51as written: GoodWe · GW4200D-NSopen the list | 2 | 4.2 | alias |
| GW4K-DT | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW4K-DTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW4K-DTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW4K-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.10as written: GoodWe · GW4K-DTopen the list | – | – | alias |
| GW5000-DNS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW5000-DNS-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW5000-DNS-30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | 2 | 5 | exact |
| GW5000-DNS-EU30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW5000-DNS-EU30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW5000-DNS-EU30open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | 2 | 5 | exact |
| GW5000-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW5000-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW5000-SDT-20 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW5000-SDT-20open the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319evidence: Protokol (EGD)as written: GoodWe · GW5000-SDT-20open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW5000-SDT-20open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.14.14.15as written: GoodWe · GW5000-SDT-20open the list | – | – | exact |
| GW5000-SDT-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW5000-SDT-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW5000-SDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04as written: GoodWe · GW5000-SDT-30open the list | – | – | alias |
| GW5000D-NS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW5000D-NSopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW5000D-NSopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW5000D-NSopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.51as written: GoodWe · GW5000D-NSopen the list | 2 | 5 | alias |
| GW50K-MT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW50K-MTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW50K-SDT-C30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW50K-SDT-C30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.01.01as written: GoodWe · GW50K-SDT-C30open the list | – | – | exact |
| GW50KN-MT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW50KN-MTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW50KN-MTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW50KN-MTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.13as written: GoodWe · GW50KN-MTopen the list | 4 | 50 | alias |
| GW50KS-MT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW50KS-MTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW50KS-MTopen the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: FW: V1.10.10; DSP FW: 10.10620.10.xx ; ARM FW: 23.460; Commu…evidence: Certifikát (SZÚ)as written: GoodWe · GW50KS-MTopen the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW50KS-MT ( kasutamiseks tööstuskeskkonnas )open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW50KS-MTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04.15as written: GoodWe · GW50KS-MTopen the list | – | – | alias |
| GW5K-DT | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW5K-DTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW5K-DTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW5K-DTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW5K-DTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.10as written: GoodWe · GW5K-DTopen the list | – | – | alias |
| GW6000-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW6000-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW6000-SDT-20 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW6000-SDT-20open the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319evidence: Protokol (EGD)as written: GoodWe · GW6000-SDT-20open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW6000-SDT-20open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.14.14.15as written: GoodWe · GW6000-SDT-20open the list | – | – | exact |
| GW6000-SDT-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW6000-SDT-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW6000-SDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04as written: GoodWe · GW6000-SDT-30open the list | – | – | alias |
| GW6000D-NS | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.51as written: GoodWe · GW6000D-NSopen the list | 2 | 6 | exact |
| GW60K-MT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW60K-MTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW60K-SMT-G20 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.01.01as written: GoodWe · GW60K-SMT-G20open the list | – | – | exact |
| GW60KN-MT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW60KN-MTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW60KN-MTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW60KN-MTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.13as written: GoodWe · GW60KN-MTopen the list | 4 | 60 | alias |
| GW60KS-MT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW60KS-MTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW60KS-MTopen the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: FW: V1.10.10; DSP FW: 10.10620.10.xx ; ARM FW: 23.460; Commu…evidence: Certifikát (SZÚ)as written: GoodWe · GW60KS-MTopen the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW60KS-MT ( kasutamiseks tööstuskeskkonnas )open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW60KS-MTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04.15as written: GoodWe · GW60KS-MTopen the list | – | – | alias |
| GW6K-DT | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW6K-DTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW6K-DTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW6K-DTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW6K-DTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.10as written: GoodWe · GW6K-DTopen the list | – | – | alias |
| GW700-XS | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - <= 800W Anlage”as written: Goodwe · GW700-XSopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW700-XSopen the list | CZ · nothing known: a certificate is required, no document foundCzechia has no list for this class; the grid operator checks the maker's certificate with the applicationwhat applies there | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW700-XSopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW700-XSopen the list | PL · nothing known: a certificate is required, no document foundPoland has no list for this class; the grid operator checks the maker's certificate with the applicationwhat applies there | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.52as written: GoodWe · GW700-XSopen the list | 1 | 0.7 | alias |
| GW700-XS-11 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW700-XS-11open the list | CZ · nothing known: a certificate is required, no document foundCzechia has no list for this class; the grid operator checks the maker's certificate with the applicationwhat applies there | EE · nothing known: a certificate is required, no document foundEstonia has no list for this class; the grid operator checks the maker's certificate with the applicationwhat applies there | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW700-XS-11open the list | PL · nothing known: a certificate is required, no document foundPoland has no list for this class; the grid operator checks the maker's certificate with the applicationwhat applies there | ✕SE · not fit: not allowedSweden does not allow this kind of device to be connectedwhat applies there | – | – | exact |
| GW700-XS-30 | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW700-XS-30open the list | CZ · nothing known: a certificate is required, no document foundCzechia has no list for this class; the grid operator checks the maker's certificate with the applicationwhat applies there | EE · nothing known: a certificate is required, no document foundEstonia has no list for this class; the grid operator checks the maker's certificate with the applicationwhat applies there | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW700-XS-30open the list | PL · nothing known: a certificate is required, no document foundPoland has no list for this class; the grid operator checks the maker's certificate with the applicationwhat applies there | ✕SE · not fit: not allowedSweden does not allow this kind of device to be connectedwhat applies there | – | – | exact |
| GW75K-HT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW75K-HTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW75K-SMT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW75K-SMTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.01.01as written: GoodWe · GW75K-SMTopen the list | – | – | exact |
| GW8000-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW8000-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW8000-SDT-20 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW8000-SDT-20open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW8000-SDT-20open the list | ✓CZ · on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21approved firmware: V1.22.22.23; DSP: 22.1286.22.--; ARM: 23.319evidence: Protokol (EGD)as written: GoodWe · GW8000-SDT-20open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW8000-SDT-20open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.12.12.13as written: GoodWe · GW8000-SDT-20open the list | – | – | exact |
| GW8000-SDT-30 | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: DSP FW:05.5008.05.5005; ARM FW:04.46; Communication Module F…as written: Goodwe · GW8000-SDT-30open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GoodWe · GW8000-SDT-30open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓PL · on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26firmware: Główny SVN: 2011, podrzędny SVN: 2003document: 6275788.01 COCas written: GoodWe Technologies Co., Ltd. · GW8000-SDT-30open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.04.04as written: GoodWe · GW8000-SDT-30open the list | – | – | alias |
| GW80K-HT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW80K-HTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
| GW80K-MT | ✕AT · not fit: the list says noWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Nein”as written: Goodwe · GW80K-MTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW80K-MTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW80K-MTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW80K-MTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.13as written: GoodWe · GW80K-MTopen the list | 4 | 80 | alias |
| GW80K-SMT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW80K-SMTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | EE · nothing known: not found on the listInverterite nimekiri (Elektrilevi)the list may spell the model differently — never “not approved”open the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.01.01as written: GoodWe · GW80K-SMTopen the list | – | – | exact |
| GW8K-DT | ✓AT · on the list, with a conditionWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list says: “Ja - mit Einschränkung”restriction applies from firmware: V1.17.17.18; Vmax PV: 950 V DCas written: Goodwe · GW8K-DTopen the list | ✓BE · on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30as written: GOODWE · GW8K-DTopen the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW8K-DTopen the list | ✓NL · on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30as written: GoodWe · GW8K-DTopen the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | ✓SE · on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23firmware: V1.10as written: GoodWe · GW8K-DTopen the list | – | – | alias |
| GW9000-DT | AT · nothing known: not found on the listWechselrichterliste TOR Erzeuger Typ A, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | BE · nothing known: not found on the listSynergrid C10/26 — list of power-generating units compliant with C10/11, dated 2026-10-30the list may spell the model differently — never “not approved”open the list | CZ · nothing known: not found on the listSeznam schválených střídačů a otestovaných ochran, dated 2026-08-21the list may spell the model differently — never “not approved”open the list | ✓EE · on the listInverterite nimekiri (Elektrilevi)as written: GoodWe Power Supply Technology Co., Ltd. · GW9000-DTopen the list | NL · nothing known: not found on the listGoedgekeurde omvormers type A (opwek + opslag), dated 2026-10-30the list may spell the model differently — never “not approved”open the list | PL · nothing known: not found on the listWykaz urządzeń (WiPWC 1.3), dated 2026-10-26the list may spell the model differently — never “not approved”open the list | SE · nothing known: not found on the listRikta Rätt — växelriktare för solceller, dated 2026-10-23the list may spell the model differently — never “not approved”open the list | – | – | alias |
MPPT count and rated kW are the maker's own datasheets, model code exactly as the sheet writes it:GW_XS_Datasheet-EN.pdf, seen 2026-10-31; GW_SMT_Datasheet-EN.pdf, seen 2026-10-31; GW_DNSx20G3_Datasheet-EN.pdf, seen 2026-10-31; GW_DNS_Datasheet-EN.pdf, seen 2026-10-31; GW_MT_Datasheet-EN.pdf, seen 2026-10-31. “–” = not collected.
How old the evidence is
Last 12 months. ◂ = older than the axis.